Spectrograph MS10-HR

Superior, Cost-Effective Performance

The MS10-HR spectrograph offers superior, cost-effective performance with high-throughput (f/2) and low stray light (<10-3), combined with rugged construction and precisely machined parts that require no mechanical or optical adjustment. The MS10-HR miniature dual-beam spectrograph disperses sample and reference spectra onto a single 0.5” photodiode array, saving costs on electronics and detectors and providing a real-time reference channel to monitor source/lamp drift.

 

Central to the design is Holographix’ aberration-corrected diffractive grating, which provides exceptionally low stray light, outstanding spectral and spatial resolution, and easy adjustment of wavelength and focus. Many standard and custom grating designs and configurations are available to meet a wide range of application requirements.

 

The MS10-HR single-beam and MD10 dual-beam optical modules are also based on aberration-corrected diffractive optics for high resolution, low stray light, high throughput, and excellent spatial imaging. They are cost-effective, versatile and easily customized for use with a variety of CCD or PDA detectors. As with the MD5, these spectrographs also offer easy adjustment of wavelength and focus and accept both free-space and fiber optic-coupled inputs.

Providing Value during Each Stage of Product Development

Optical Design

Exceptional Performance

Development Flexibility

Manufacturing Excellence

MS10 spectrograph

Spectrograph MS10-HR Applications:

  • Precision Color Measurement
  • Biomedical
  • Research
  • Forensics
  • Process Monitoring

 

Optimize level of integration with collaborative engineering to enable Customer Innovation

MS10-HR Spectrograph Design Example:

Presented below are example standard capabilities of our MS10-HR spectrograph. Many of the listed specifications can be optimized to meet your specific application requirements, including Spectral Passband, Spectral Sampling Interval and Spectral Resolution.

Design Parameters Standard Capability Examples
Spectral passband 290-500 nm
Spectral Sampling Interval (dispersion per pixel) 0.42 nm/pixel
Spectral Resolution (slit width dependent) 2.5 nm
Dimensions (mm) 105L x 76W x 50H
Numerical Aperture 0.18
Light Coupling SMA or Ferrule type
Number of Channels Single Channel

Talk to Our Experts

For any questions or to request a MS10 quote, please fill out the contact form below.

Spectrograph MS10
Choose your State or Province for the US and Canada. Otherwise, please choose Other or None.

More Spectrographs

Headwall MD5 Spectrograph
spectrograph-MD-5
Headwall MD10 Spectrograph
spectrograph-MD-10
Headwall MS10 Spectrograph
MS10 spectrograph
 Headwall Raman Spectrograph
Raman Explorer OEM Spectrograph

Please Contact Our Experts to Discuss Your Requirements.

Contact   

Please Contact Our Experts to Discuss Your Requirements.

   Contact